Argon Medical Devices, Inc recalls
23 recalls in our records from 2012 to 2026: 23 FDA medical devices.
Recalls with full detail pages
-
Argon Medical Devices, Inc medical device recall: Transvenous Pacing Electrode Tray w/ Bipolar Balloon Pacing Electrode…
Kits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility.
Earlier and other recalls
These link to the official agency notice.
-
Argon Medical Devices, Inc medical device recall: L-Cath PICC S/L Peripherally Inserted Central Catheter: 26ga Official notice ↗
Catheters, indicated for short/long-term peripheral access to central venous system for the administration of fluids, medications, nutrients; and sampling, may…
-
Argon Medical Devices, Inc medical device recall: Option"ELITE Vena Cava Filter System REF 352506070E UDI-DI code:… Official notice ↗
Due to complaints of increased resistance when advancing the dilator within the introducer sheath. This issue could potential result in procedural delays and/or risk of…
-
Argon Medical Devices, Inc medical device recall: BioPince Ultra Full Core Biopsy Instrument: REF: REF: 360-1080-01 Official notice ↗
Holes have been identified in biopsy instrument packaging trays compromising the sterile barrier, which may lead to cross contamination, or the introduction of…
-
Argon Medical Devices, Inc medical device recall: L-CATH PICC S/L Peripherally Inserted Central Catheter Official notice ↗
Peripherally Inserted Central Catheter (PICC) is labeled 26G/1.9Fr x 30cm but package contains incorrect 26G/1.9Fr x 50cm PICC, which could lead to procedural delay.
-
Argon Medical Devices, Inc medical device recall: Argon Medical Devices Official notice ↗
There is the potential that the vena Cava Filter may not perform as intended which may result in pulmonary embolism.
-
Argon Medical Devices, Inc medical device recall: 1. Arterial Line Kit 20ga x 6" 2. Arterial Line Kit /1 20ga x 6 Official notice ↗
Guidewire included with two lots of Arterial Line Kits would not fit through the needle of the same kit. This could potentially lead to a slight delay in the procedure…
-
Argon Medical Devices, Inc medical device recall: SuperCore Biopsy Instrument: REF/Product Description:… Official notice ↗
Due to component (housing and plunger) detaching from the semi-automatic biopsy instruments.
-
Argon Medical Devices, Inc medical device recall: Scorpion Portal Vein Access Set - Product Usage: used to gain access… Official notice ↗
As a result of design changes, sheaths have exhibited cracking/breaking at the tips.
-
Argon Medical Devices, Inc medical device recall: Argon Medical Devices TLAB Official notice ↗
Due to a manufacturing error their is a potential that the sheath within the biopsy kit can separate during use if the tip is flexed or experiences bending stresses.…
-
Argon Medical Devices, Inc medical device recall: ClosureFast Micro Introducer Sheath Set Official notice ↗
Sterile introducer sheath set manufactured under one lot with different expiration dates.
-
Argon Medical Devices, Inc medical device recall: BioPince Full Core Biopsy Instrument 16ga x 15cm Official notice ↗
Incorrect product labeling.
-
Argon Medical Devices, Inc medical device recall: Skater Introducer Set 6F x 18cm. REF/UDI: 651506300/(01)00886333005000 Official notice ↗
Tungsten coils of the guidewire included in the introducer kit were detaching.
-
Argon Medical Devices, Inc medical device recall: Arterial Line Kit 20ga X 3 Official notice ↗
Arterial Line Kits include thicker curved reverse-cutting needle with a 0-silk suture, instead of the usual straight-cutting needle with a 3-0 silk suture. The thicker…
-
Argon Medical Devices, Inc medical device recall: 0.035"(.89mm)x80 cm guidewire. Model 114135080. Soft Tip 3.5cm.… Official notice ↗
The stiffness of the soft end of the guidewire caused tissue perforation.
-
Argon Medical Devices, Inc medical device recall: (1) Argon Medical Devices Double Female LL Adapter Official notice ↗
The seal formed on the edge of the pouch may be incomplete, which could result in a loss of sterility to the product.
-
Argon Medical Devices, Inc medical device recall: Clear Flashback Needle 7cm x 18G AMC/4 Official notice ↗
Argon Medical has received a complaint from one of their distributors of a potential packaging defect. The product is sealed in a pouch and the defect if present shows…
-
Argon Medical Devices, Inc medical device recall: BONE MARROW ASPIRATION NEEDLE 15G x 2.688 MAX and 15G x 4 MAX… Official notice ↗
The recalling firm received a complaint from one of their customers of a potential defect in the forming of the primary package of the blister that may compromise the…
-
Argon Medical Devices, Inc medical device recall: MicroStic Plus w/SS Wire 5F and MicroStic Plus w/NiTi Wire & Echo… Official notice ↗
The supplier initiated a recall because affected lots of the micro-introducer have an outer diameter of the dilator hub that is slightly smaller than is capable of…
-
Argon Medical Devices, Inc medical device recall: ClosureFast Micro Introducer Sheath Set 7Fr/Ch(2.3mm) x 7 cm REF… Official notice ↗
The incorrect sheath was assembled to the device so that the size 7 products received 11 cm sheaths and the size 11 product received 7 cm sheaths.
-
Argon Medical Devices, Inc medical device recall: Bone Marrow Aspiration Needle 15G x 2.688 MAX Official notice ↗
Potential defect in the forming of the primary package of the blister that may compromise the sterility of the product inside the tray.
-
Argon Medical Devices, Inc medical device recall: UltraStream Chronic Hemodialysis Catheter Standard Kit Official notice ↗
UltraStream Chronic Hemodialysis Catheter may develop cracks on the red (arterial) luer during attachment or manipulation.
-
Argon Medical Devices, Inc medical device recall: Safedraw Venous Close Loop System Official notice ↗
Some of the kits may exhibit a potential defect with the pouch seal. The pouch issue may compromise the sterile barrier.