RecallRadar
FDA · Medical devicesClass I

Tandem Diabetes Care, Inc. medical device recall: t:slim X2 Insulin Pump with Interoperable Technology

LeadSoftware problems

Key facts

Agency
U.S. Food and Drug Administration (FDA)
Program
Medical devices
Classification
Class I
Status
Ongoing
Event ID
96417
Recall initiated
Feb 27, 2025
Classified by FDA
Apr 11, 2025
Posted in Enforcement Report
Apr 23, 2025
Recalling firm
Tandem Diabetes Care, Inc.
Firm location
San Diego, CA, United States
Initiated by
Voluntary: Firm initiated
Firm notified customers by
Telephone
Products in this event
2

What to do

Compare the product, lot or serial numbers below with what you have. If you use a prescription drug or medical device in this recall, talk to your pharmacist or health care provider before you stop using it, and follow the firm's instructions.

View the official FDA record ↗

Reason for recall

A software defect in Version 7.9 of the pump software for Tandem t:slim X2 and Tandem Mobi pumps, when used with Control IQ+ technology, will cause the pump to incorrectly interpolate glucose trends when the Estimated Glucose Value (EGV) is above 255 mg/dL at the start or end of a gap in data collection due to a lapse in connection from a paired continuous glucose monitor (CGM) sensor, which can lead to under-delivery or over-delivery of insulin based on inaccurate result leading to severe cases of hypoglycemia or hyperglycemia.

What the classification means

  • Class I: FDA's most serious category: there is a reasonable probability that using or being exposed to the product will cause serious health problems or death.

About this recall

The firm started this recall on Feb 27, 2025. FDA classified it 43 days later, on Apr 11, 2025. This recall event covers 2 separate products, each with its own FDA recall number. Distribution reported by FDA: US: AZ, CA, CO, CT, FL, HI, IA, ID, IL, IN, MD, ME, MI, MO, MS, NC, ND, NE, NJ, NM, NV, NY, OH, PA, TX, UT, VA, WA, WI OUS: N/A Tandem Diabetes Care, Inc. has 12 recalls in our records.

Recalled products (2)

  • Z-1519-2025 Class I Ongoing

    t:slim X2 Insulin Pump with Interoperable Technology

    Codes / lots: Software versions 7.9/UDI: 00389152407012

    Quantity: 63 units

  • Z-1520-2025 Class I Ongoing

    Tandem Mobi Insulin Pump with Interoperable Technology

    Codes / lots: Software versions 7.9/UDI: 00389152480114

    Quantity: 85 units

Source and freshness

Source
U.S. Food and Drug Administration (FDA) Enforcement Report, via the openFDA device enforcement dataset
Official notice
FDA Enforcement Report, event 96417
Raw record
openFDA API (JSON)
Dataset last updated by FDA
Nov 3, 2026
Imported by RecallRadar
Nov 4, 2026

Enforcement Report entries describe recalls FDA has classified. They are not always the same as a company press release. If something here differs from FDA's record, FDA's record is correct — please tell us.

More recalls from this firm