RecallRadar
FDA · Medical devicesClass I

Fresenius Kabi USA, LLC medical device recall: Ivenix Infusion System

Key facts

Agency
U.S. Food and Drug Administration (FDA)
Program
Medical devices
Classification
Class I
Status
Ongoing
Event ID
98945
Recall initiated
May 6, 2026
Classified by FDA
May 29, 2026
Posted in Enforcement Report
Jun 10, 2026
Recalling firm
Fresenius Kabi USA, LLC
Firm location
North Andover, MA, United States
Initiated by
Voluntary: Firm initiated
Firm notified customers by
E-Mail
Products in this event
1

What to do

Compare the product, lot or serial numbers below with what you have. If you use a prescription drug or medical device in this recall, talk to your pharmacist or health care provider before you stop using it, and follow the firm's instructions.

View the official FDA record ↗

Reason for recall

Fresenius Kabi has been made aware via customer complaints that dropping or severe jarring of the Ivenix LVP may cause damage to internal components that may not be apparent or readily visible and the devices therefore remained in service. More specifically, drops or jarring on a hard surface can cause the touchscreen input cable to loosen, resulting in unintended touchscreen behavior on the LVP, including random screen touches and/or lack of screen responsiveness to user input. Under the reported failure condition, unintended touch inputs may register at arbitrary screen locations without user interaction. These inputs occur intermittently and without a predictable pattern.

What the classification means

  • Class I: FDA's most serious category: there is a reasonable probability that using or being exposed to the product will cause serious health problems or death.

About this recall

The firm started this recall on May 6, 2026. FDA classified it 23 days later, on May 29, 2026. Distribution reported by FDA: Domestic: CA, CO, FL, GA, ID, IL, MD, MI, MI , MN, MO, MS, NE, NJ, NV, OK, OR, SC, TX, VA, WA, WI, WI; Fresenius Kabi USA, LLC has 67 recalls in our records.

Recalled products (1)

  • Z-2224-2026 Class I Ongoing

    Ivenix Infusion System (IIS), Large Volume Pump, Model Number: LVP-0004

    Codes / lots: Model Number: LVP-0004; UDI-DI: 00811505030320; All Serial/Lot Numbers:

    Quantity: 18,444

Source and freshness

Source
U.S. Food and Drug Administration (FDA) Enforcement Report, via the openFDA device enforcement dataset
Official notice
FDA Enforcement Report, event 98945
Raw record
openFDA API (JSON)
Dataset last updated by FDA
Nov 3, 2026
Imported by RecallRadar
Nov 4, 2026

Enforcement Report entries describe recalls FDA has classified. They are not always the same as a company press release. If something here differs from FDA's record, FDA's record is correct — please tell us.

More recalls from this firm