RecallRadar
FDA · Medical devicesClass I

Boston Scientific Neuromodulation Corporation medical device recall: Infinion Cx Lead Kit

Lead

Key facts

Agency
U.S. Food and Drug Administration (FDA)
Program
Medical devices
Classification
Class I
Status
Ongoing
Event ID
98974
Recall initiated
Jun 17, 2026
Classified by FDA
Aug 5, 2026
Posted in Enforcement Report
Aug 12, 2026
Recalling firm
Boston Scientific Neuromodulation Corporation
Firm location
Valencia, CA, United States
Initiated by
Voluntary: Firm initiated
Firm notified customers by
Letter
Products in this event
1

What to do

Compare the product, lot or serial numbers below with what you have. If you use a prescription drug or medical device in this recall, talk to your pharmacist or health care provider before you stop using it, and follow the firm's instructions.

View the official FDA record ↗

Reason for recall

Spinal cord stimulation system lead body may be exposed to stress at the anchor site. This may result in high impedance measurements or lead fractures, which may lead to inadequate stimulation, additional intervention, including lead explant and replacement.

What the classification means

  • Class I: FDA's most serious category: there is a reasonable probability that using or being exposed to the product will cause serious health problems or death.

About this recall

The firm started this recall on Jun 17, 2026. FDA classified it 49 days later, on Aug 5, 2026. Distribution reported by FDA: US: NY. OUS: Canada, Portugal, Spain, France, Netherlands, Great Britain, Italy, Israel, Serbia, Greece, Germany, United Arab Emirates, Ireland, Hungary, Czech Republic, Brazil, Colombia, Argentina Boston Scientific Neuromodulation Corporation has 13 recalls in our records.

Recalled products (1)

  • Z-2879-2026 Class I Ongoing

    INFINION CX LEAD KIT, 50CM, Model: SC-2317-50, Material: M365SC2317500; INFINION CX LEAD KIT, 70CM, Model: SC-2317-70, Material: M365SC2317700. part of the Boston Scientific Spinal Cord Stimulator (SCS) Systems.

    Codes / lots: Model/UDI-DI: SC-2317-50/08714729861614, SC-2317-70/08714729861638. All unused products.

    Quantity: 1079

Source and freshness

Source
U.S. Food and Drug Administration (FDA) Enforcement Report, via the openFDA device enforcement dataset