RecallRadar
FDA · Medical devicesClass I

Medline Industries, LP medical device recall: MEDLINE beds labeled as: 1) Semi Electric Basic Homecare Bed

Key facts

Agency
U.S. Food and Drug Administration (FDA)
Program
Medical devices
Classification
Class I
Status
Ongoing
Event ID
98185
Recall initiated
Nov 26, 2025
Classified by FDA
Jan 16, 2026
Posted in Enforcement Report
Jan 28, 2026
Recalling firm
Medline Industries, LP
Firm location
Northfield, IL, United States
Initiated by
Voluntary: Firm initiated
Firm notified customers by
Letter
Products in this event
6

What to do

Compare the product, lot or serial numbers below with what you have. If you use a prescription drug or medical device in this recall, talk to your pharmacist or health care provider before you stop using it, and follow the firm's instructions.

View the official FDA record ↗

Reason for recall

Medline Industries has identified a potential hazard involving the hand control pendant and associated wires. In rare and atypical scenarios such as operating the bed above its specified weight limit, encountering an obstruction to bed movement, or experiencing jammed components/motor the hand pendant and pendant cords may overheat and, in rare instances, pose a risk of fire. Medline Industries, LP has received a total of (58) complaints associated with reports of pendant sparking, burning, melting, smoking or fire.

What the classification means

  • Class I: FDA's most serious category: there is a reasonable probability that using or being exposed to the product will cause serious health problems or death.

About this recall

The firm started this recall on Nov 26, 2025. FDA classified it 51 days later, on Jan 16, 2026. This recall event covers 6 separate products, each with its own FDA recall number. Distribution reported by FDA: US, CA, PA, GUAM, VI Medline Industries, LP has 257 recalls in our records.

Recalled products (6)

  • Z-1011-2026 Class I Ongoing

    MEDLINE beds labeled as: 1) Semi Electric Basic Homecare Bed, REF MDR107002E; 2) Semi Electric Basic Homecare Bed, 4-pack,REF MDR107002E-4

    Codes / lots: 1) UDI/DI 40080196320999, All lots; 2) UDI/DI 40080196320999, All Lots

    Quantity: 373392 units

  • Z-1012-2026 Class I Ongoing

    MEDLINE beds labeled as: Semi Electric Lightweight Homecare Bed, REF MDR107002L

    Codes / lots: UDI/DI 40080196294320, All lots

    Quantity: 13245 units

  • Z-1013-2026 Class I Ongoing

    MEDLINE beds labeled as: 1) Full Electric Basic Homecare Bed, REF MDR107003E; 2) Full Electric Basic Homecare Bed, 4-pack,REF MDR107003E-4.

    Codes / lots: 1) REF MDR107003E, UDI/DI 40080196321002, All lots; 2) REF MDR107003E-4, UDI/DI 40080196321002, All lots

    Quantity: 138412 units

  • Z-1014-2026 Class I Ongoing

    MEDLINE beds labeled as: Full Electric Low Basic Homecare Bed, REF MDR107003ELO

    Codes / lots: UDI/DI 10080196546992, All lots

    Quantity: 22565 units

  • Z-1015-2026 Class I Ongoing

    MEDLINE beds labeled as: Full Electric Lightweight Homecare Bed, REF MDR107003L

    Codes / lots: UDI/DI 40080196294344, All lots

    Quantity: 35694 units

  • Z-1016-2026 Class I Ongoing

    MEDLINE beds labeled as: Full Electric Low Lightweight Homecare Bed, REF MDR107003LO

    Codes / lots: UDI/DI 40080196325901, All lots

    Quantity: 15581 units

Source and freshness

Source
U.S. Food and Drug Administration (FDA) Enforcement Report, via the openFDA device enforcement dataset